Flow Accumulation (QM of ESP)
- Author: O.Conrad (c) 2013
- Menu: Terrain Analysis | Hydrology | Flow Accumulation | Alternatives
Description
Calculation of flow accumulation, aka upslope contributing area, with the multiple flow direction method after Freeman (1991).
References
- Freeman, G.T. (1991): Calculating catchment area with divergent flow based on a rectangular grid. Computers & Geosciences, 17, pp.413-422.
- Pelletier, J.D. (2008): Quantitative Modeling of Earth Surface Processes. Cambridge, 295p.
Parameters
|  | Name | Type | Identifier | Description | Constraints | 
|---|
| Input | DEM | grid, input | DEM | - | - | 
| Output | Contributing Area | grid, output | FLOW | - | - | 
| Options | Grid System | grid system | PARAMETERS_GRID_SYSTEM | - | - | 
| Preprocessing | choice | PREPROC | - | Available Choices:
[0] none
[1] fill sinks temporarily
[2] fill sinks permanently
Default: 1 | 
| Fill Increment | floating point number | DZFILL | - | Minimum: 0.000000
Default: 0.010000 | 
Command Line
Usage: saga_cmd sim_qm_of_esp 2 [-DEM ] [-FLOW ] [-PREPROC ] [-DZFILL ]
  -DEM:      	DEM
	grid, input
  -FLOW:     	Contributing Area
	grid, output
  -PREPROC:  	Preprocessing
	choice
	Available Choices:
	[0] none
	[1] fill sinks temporarily
	[2] fill sinks permanently
	Default: 1
  -DZFILL:	Fill Increment
	floating point number
	Minimum: 0.000000
	Default: 0.010000