SAGA 9.3.3 | Tool Library Documentation

Cold Air Flow


Description

A simple cold air flow simulation.


References


Parameters

 NameTypeIdentifierDescriptionConstraints
InputElevationgrid, inputDEM--
Productiongrid, input, optionalPRODUCTIONRate of cold air production [m/h].-
Surface Friction Coefficientgrid, input, optionalFRICTIONSurface friction coefficient.-
OutputCold Air Heightgrid, outputAIR--
Velocitygrid, output, optionalVELOCITY--
OptionsGrid Systemgrid systemPARAMETERS_GRID_SYSTEM--
Defaultfloating point numberPRODUCTION_DEFAULTdefault value if no grid has been selectedMinimum: 0.000000 Default: 1.000000
Defaultfloating point numberFRICTION_DEFAULTdefault value if no grid has been selectedMinimum: 0.000000 Default: 1.000000
ResetbooleanRESET-Default: 1
Simulation Time [h]floating point numberTIME_STOPSimulation time in hours.Minimum: 0.000000 Default: 6.000000
Map Update Frequency [min]floating point numberTIME_UPDATE-Minimum: 0.000000 Default: 10.000000
EdgechoiceEDGE-Available Choices: [0] closed [1] open Default: 1
Time Step Adjustmentfloating point numberDELAYChoosing a lower value will result in a better numerical precision but also in a longer calculation time.Minimum: 0.010000 Maximum: 1.000000 Default: 0.500000
Surrounding Air Temperaturefloating point numberT_AIRSurrounding air temperature [degree Celsius].Minimum: -273.150000 Default: 15.000000
Cold Air Temperaturefloating point numberT_AIR_COLDCold air temperature [degree Celsius].Minimum: -273.150000 Default: 5.000000

Command Line


Usage: saga_cmd sim_air_flow 0 [-DEM ] [-PRODUCTION ] [-PRODUCTION_DEFAULT ] [-FRICTION ] [-FRICTION_DEFAULT ] [-AIR ] [-VELOCITY ] [-RESET ] [-TIME_STOP ] [-TIME_UPDATE ] [-EDGE ] [-DELAY ] [-T_AIR ] [-T_AIR_COLD ]
  -DEM:                  	Elevation
	grid, input
  -PRODUCTION:           	Production
	grid, input, optional
  -PRODUCTION_DEFAULT:	Default
	floating point number
	Minimum: 0.000000
	Default: 1.000000
  -FRICTION:             	Surface Friction Coefficient
	grid, input, optional
  -FRICTION_DEFAULT:  	Default
	floating point number
	Minimum: 0.000000
	Default: 1.000000
  -AIR:                  	Cold Air Height
	grid, output
  -VELOCITY:             	Velocity
	grid, output, optional
  -RESET:                	Reset
	boolean
	Default: 1
  -TIME_STOP:         	Simulation Time [h]
	floating point number
	Minimum: 0.000000
	Default: 6.000000
  -TIME_UPDATE:       	Map Update Frequency [min]
	floating point number
	Minimum: 0.000000
	Default: 10.000000
  -EDGE:                 	Edge
	choice
	Available Choices:
	[0] closed
	[1] open
	Default: 1
  -DELAY:             	Time Step Adjustment
	floating point number
	Minimum: 0.010000
	Maximum: 1.000000
	Default: 0.500000
  -T_AIR:             	Surrounding Air Temperature
	floating point number
	Minimum: -273.150000
	Default: 15.000000
  -T_AIR_COLD:        	Cold Air Temperature
	floating point number
	Minimum: -273.150000
	Default: 5.000000