SAGA 9.6.1 | Tool Library Documentation

Overland Flow


Description

A simple overland flow simulation.


Parameters

 NameTypeIdentifierDescriptionConstraints
InputElevationgrid, inputDEM--
Roughnessgrid, input, optionalROUGHNESSKs Strickler = 1/n Manning-
Interception Capacity [mm]grid, input, optionalINTER_MAX--
Ponding Capacity [mm]grid, input, optionalPOND_MAX--
Infiltration Capacity [mm/h]grid, input, optionalINFIL_MAX--
Flow [mm]grid, input, optionalFLOW--
Precipitation [mm/h]grid, input, optionalPRECIP--
Potential Evapotranspiration [mm/h]grid, input, optionalET_POT--
Monitorsshapes, input, optionalMONITOR_POINTS--
OutputInterception [mm]grid, outputINTERCEPT--
Ponding [mm]grid, outputPONDING--
Infiltration [mm]grid, outputINFILTRAT--
Velocity [m/h]grid, output, optionalVELOCITY--
Overland Flow Summarytable, output, optionalSUMMARY--
Time Seriestable, outputMONITOR_SERIESFlow accumulation values collected for each monitor point.-
OptionsGrid Systemgrid systemPARAMETERS_GRID_SYSTEM--
Defaultfloating point numberROUGHNESS_DEFAULTdefault value if no grid has been selectedMinimum: 0.000000 Default: 20.000000
TypechoiceSTRICKLERKs Strickler = 1/n Gauckler-ManningAvailable Choices: [0] Strickler Ks, [m^1/3 / s] [1] Gauckler-Manning n, [s / m^1/3] Default: 0
Defaultfloating point numberINTER_MAX_DEFAULTdefault value if no grid has been selectedMinimum: 0.000000 Default: 0.000000
Defaultfloating point numberPOND_MAX_DEFAULTdefault value if no grid has been selectedMinimum: 0.000000 Default: 0.000000
Defaultfloating point numberINFIL_MAX_DEFAULTdefault value if no grid has been selectedMinimum: 0.000000 Default: 0.000000
Weather Grid Systemgrid systemWEATHER--
Defaultfloating point numberPRECIP_DEFAULTdefault value if no grid has been selectedMinimum: 0.000000 Default: 0.000000
Defaultfloating point numberET_POT_DEFAULTdefault value if no grid has been selectedMinimum: 0.000000 Default: 0.000000
ResetbooleanRESETIf checked storages (flow, ponding, interception) and sinks (infiltration) will be set to zero.Default: 1
Simulation Time [h]floating point numberTIME_STOPSimulation time in hours.Minimum: 0.000000 Default: 6.000000
Time Step Adjustmentfloating point numberTIME_STEPChoosing a lower value will result in a better numerical precision but also in a longer calculation time.Minimum: 0.010000 Maximum: 1.000000 Default: 0.500000
Overland Flow SummarybooleanFLOW_OUTReport the amount of overland flow that left the covered area.Default: 0
Map Update Frequencyfloating point numberTIME_UPDATEMap update frequency in minutes. Set to zero to update each simulation time step.Minimum: 0.000000 Default: 1.000000
Fixed Color Stretch for FlowbooleanUPDATE_FLOW_FIXED-Default: 0
Fixed Color Stretchvalue rangeUPDATE_FLOW_RANGE--
Fixed Color Stretch for VelocitybooleanUPDATE_VELO_FIXED-Default: 1
Fixed Color Stretchvalue rangeUPDATE_VELO_RANGE--
Nametable fieldMONITOR_NAMEUsed to name time series fields. Will simply be enumerated if not set.-
Monitor Update Frequencyfloating point numberMONITOR_UPDATEMonitor update frequency in minutes. Set to zero to update each simulation time step.Minimum: 0.000000 Default: 1.000000
ResetbooleanMONITOR_RESET-Default: 0

Command Line


Usage: saga_cmd sim_hydrology 9 [-DEM ] [-ROUGHNESS ] [-ROUGHNESS_DEFAULT ] [-STRICKLER ] [-INTER_MAX ] [-INTER_MAX_DEFAULT ] [-POND_MAX ] [-POND_MAX_DEFAULT ] [-INFIL_MAX ] [-INFIL_MAX_DEFAULT ] [-INTERCEPT ] [-PONDING ] [-INFILTRAT ] [-FLOW ] [-VELOCITY ] [-PRECIP ] [-PRECIP_DEFAULT ] [-ET_POT ] [-ET_POT_DEFAULT ] [-RESET ] [-TIME_STOP ] [-TIME_STEP ] [-FLOW_OUT ] [-SUMMARY ] [-TIME_UPDATE ] [-UPDATE_FLOW_FIXED ] [-UPDATE_FLOW_RANGE_MIN ] [-UPDATE_FLOW_RANGE_MAX ] [-UPDATE_VELO_FIXED ] [-UPDATE_VELO_RANGE_MIN ] [-UPDATE_VELO_RANGE_MAX ] [-MONITOR_POINTS ] [-MONITOR_NAME ] [-MONITOR_SERIES ] [-MONITOR_UPDATE ] [-MONITOR_RESET ]
  -DEM:                     	Elevation
	grid, input
  -ROUGHNESS:               	Roughness
	grid, input, optional
  -ROUGHNESS_DEFAULT:    	Default
	floating point number
	Minimum: 0.000000
	Default: 20.000000
  -STRICKLER:               	Type
	choice
	Available Choices:
	[0] Strickler Ks, [m^1/3 / s]
	[1] Gauckler-Manning n, [s / m^1/3]
	Default: 0
  -INTER_MAX:               	Interception Capacity [mm]
	grid, input, optional
  -INTER_MAX_DEFAULT:    	Default
	floating point number
	Minimum: 0.000000
	Default: 0.000000
  -POND_MAX:                	Ponding Capacity [mm]
	grid, input, optional
  -POND_MAX_DEFAULT:     	Default
	floating point number
	Minimum: 0.000000
	Default: 0.000000
  -INFIL_MAX:               	Infiltration Capacity [mm/h]
	grid, input, optional
  -INFIL_MAX_DEFAULT:    	Default
	floating point number
	Minimum: 0.000000
	Default: 0.000000
  -INTERCEPT:               	Interception [mm]
	grid, output
  -PONDING:                 	Ponding [mm]
	grid, output
  -INFILTRAT:               	Infiltration [mm]
	grid, output
  -FLOW:                    	Flow [mm]
	grid, input, optional
  -VELOCITY:                	Velocity [m/h]
	grid, output, optional
  -PRECIP:                  	Precipitation [mm/h]
	grid, input, optional
  -PRECIP_DEFAULT:       	Default
	floating point number
	Minimum: 0.000000
	Default: 0.000000
  -ET_POT:                  	Potential Evapotranspiration [mm/h]
	grid, input, optional
  -ET_POT_DEFAULT:       	Default
	floating point number
	Minimum: 0.000000
	Default: 0.000000
  -RESET:                   	Reset
	boolean
	Default: 1
  -TIME_STOP:            	Simulation Time [h]
	floating point number
	Minimum: 0.000000
	Default: 6.000000
  -TIME_STEP:            	Time Step Adjustment
	floating point number
	Minimum: 0.010000
	Maximum: 1.000000
	Default: 0.500000
  -FLOW_OUT:                	Overland Flow Summary
	boolean
	Default: 0
  -SUMMARY:                 	Overland Flow Summary
	table, output, optional
  -TIME_UPDATE:          	Map Update Frequency
	floating point number
	Minimum: 0.000000
	Default: 1.000000
  -UPDATE_FLOW_FIXED:       	Fixed Color Stretch for Flow
	boolean
	Default: 0
  -UPDATE_FLOW_RANGE_MIN:	Fixed Color Stretch
	value range
  -UPDATE_FLOW_RANGE_MAX:	Fixed Color Stretch
	value range
  -UPDATE_VELO_FIXED:       	Fixed Color Stretch for Velocity
	boolean
	Default: 1
  -UPDATE_VELO_RANGE_MIN:	Fixed Color Stretch
	value range
  -UPDATE_VELO_RANGE_MAX:	Fixed Color Stretch
	value range
  -MONITOR_POINTS:          	Monitors
	shapes, input, optional
  -MONITOR_NAME:            	Name
	table field
  -MONITOR_SERIES:          	Time Series
	table, output
  -MONITOR_UPDATE:       	Monitor Update Frequency
	floating point number
	Minimum: 0.000000
	Default: 1.000000
  -MONITOR_RESET:           	Reset
	boolean
	Default: 0