Stream Power Index
- Author: O.Conrad (c) 2003
- Menu: Terrain Analysis | Hydrology | Topographic Indices
Description
Calculation of stream power index based on slope and specific catchment area (SCA).
SPI = SCA * tan(Slope)
References
- Moore, I.D., Grayson, R.B., Ladson, A.R. (1991): Digital terrain modelling: a review of hydrogical, geomorphological, and biological applications. Hydrological Processes, Vol.5, No.1
Parameters
| Name | Type | Identifier | Description | Constraints |
Input | Slope | grid, input | SLOPE | - | - |
Catchment Area | grid, input | AREA | - | - |
Output | Stream Power Index | grid, output | SPI | - | - |
Options | Grid System | grid system | PARAMETERS_GRID_SYSTEM | - | - |
Area Conversion | choice | CONV | - | Available Choices:
[0] no conversion (areas already given as specific catchment area)
[1] 1 / cell size (pseudo specific catchment area)
Default: 0 |
Command Line
Usage: saga_cmd ta_hydrology 21 [-SLOPE ] [-AREA ] [-SPI ] [-CONV ]
-SLOPE: Slope
grid, input
-AREA: Catchment Area
grid, input
-SPI: Stream Power Index
grid, output
-CONV: Area Conversion
choice
Available Choices:
[0] no conversion (areas already given as specific catchment area)
[1] 1 / cell size (pseudo specific catchment area)
Default: 0